The check valves are designed with metal to metal sealing, and are not 100% leak free. A leak rate of 10 drops/minute are acceptable.
Cracking pressure approx. 2 Bar
In order to prevent jamming of Stab in Receptacle the threads
has been inserted with Loctite.
Change of Valves is NOT recommended to be done Offshore
without proper training.
Stabs to be returned to Blue Logic for service of Check Valves.
These valves will only fit on Blue Logic Hot Stabs
Not sold separately.